If there is a black attachment in the mesh belt furnace, the cleaning method cannot be determined by the appearance alone. First confirm the location of the attachment, the use process and medium, the structure of the equipment and the abnormal records, and then the person in charge shall formulate the processing and review requirements according to the equipment document.
This article answers what should be prepared before carbon cleaning and how to check the processing scope. It does not provide carbon burning, atmosphere switching, opening air induction or other on-site operation steps.
Match the deposit location to the operating conditions
The attachments in the furnace, mesh belt, workpiece surface or other parts should be recorded separately. Only the sentence "the furnace is carbonized" cannot judge which systems the problem involves, and it is impossible to confirm whether they are all the same attachments.
Organize the existing photos, operation and maintenance records, and put the time of the problem together with the changes of workpiece, belt loading, temperature curve, atmosphere or use medium. The relationship in time is just to investigate the clues, and it can't be directly regarded as the reason that has been identified.
Use more than a fixed interval to define the cleaning scope
There is no fixed carbonization cycle applicable to all mesh belt furnaces. The maintenance arrangement should be confirmed in combination with the specific equipment description, conditions of use, actual status and the existing maintenance system, and the cycle, temperature or time of another equipment should not be copied.
The mesh belt, support, transmission, atmosphere and cooling configuration of the current equipment will also affect the parts that need to be checked. When the information is not complete, supplement the identity and structure information of the equipment first; when the original document is inconsistent with the site, check the transformation record together.
| Data | Issues that should be cleared |
|---|---|
| Nameplate, equipment description, structural drawing and renovation record | Whether it is the same device and the same version of the device is discussed. |
| The location of the attachment and the existing photos and abnormal records | Which parts are affected and when will the phenomenon appear? |
| Workpiece, belt loading, process and media record | What are the operating conditions when the problem occurs? |
| Records of previous cleaning, repair and replacement | Which parts have been dealt with and whether the problem occurs again |
| Maintenance and review requirements in equipment documents | Who will confirm the specific plan and how to verify it after completion? |
Check that the original issue has been resolved
The completion of the cleaning work does not mean that the transportation and workpiece results have been restored. The review project shall be agreed upon according to the actual processing scope, and the records of the processing part, equipment status, conveying performance and applicable process verification shall be kept respectively.
If the problem occurs repeatedly, the before and after work conditions and processing records should be put together for further analysis. You can't just remember "cleaned up" at a time. The comparison should match the same workpiece, belt loading and process conditions as much as possible, otherwise it is difficult to judge whether the change comes from the processing work or the production conditions are different.
Agree the scope of work using the equipment records
You can first prepare the equipment model, the location of the attachment, the recent major changes, the past processing records and the planned maintenance window, and then refer to Mesh belt furnace structure and applicable conditions Catch up Maintenance and renovation services for industrial furnaces Communication information gaps and evaluation scope.
Whether to undertake the specific cleaning work, what method is adopted, and what personnel and supporting equipment are needed should be confirmed separately according to the equipment and on-site conditions. This article does not eq. the preliminary communication of the data is equivalent to the approval of the carbon cleaning plan.