Can a mesh belt furnace reach its specified maximum output when quenching and tempering my U-bolts?

Published苏能工业炉工程技术团队&唐荔

The maximum output in the specification table is an upper limit. To establish throughput for your U-bolt, first give the supplier the drawing and the proposed arrangement on the belt. With the same belt width, changes in bolt shape and spacing still change how many parts fit on each section of belt.

Ask the supplier to quote against your drawings

A standard-parts mesh belt quench and temper line agreement from Jiangsu Suneng Industrial Furnace Co., Ltd. (Suneng) lists standard parts, hardware parts and U-bolts as workpieces. Its equipment specification states a maximum quenching-and-tempering throughput of approximately 1500 kg/h, varying with part dimensions, material and heat-treatment requirements. To use this information for your own orders, choose a frequently produced bolt and another that is difficult to arrange on the belt, and ask the supplier to complete the following comparison.

Information you provideWhat you want the supplier to return
Representative drawing, unit weight and proposed loading arrangementHourly throughput calculated for this part and arrangement
Material and quenching and tempering requirementsProcess conditions used for the quoted figure
Another common size or one that is harder to scheduleConditions that must change for a different size and whether throughput must be recalculated
Maximum approx. 1500 kg/h for quenching and tempering: this project's specification limit. Give the supplier; Bolt drawings and unit weights; Arrangement on the belt; Material and treatment needs. Ask the supplier for; Output calculated for this bolt; Loading and process conditions; What to recheck for another size. Schedule your orders using the figure calculated for your parts.

What else can the specification table tell you?

This agreement specifies a main furnace belt width of 1000 mm and a heated zone length of 12000 mm. Main furnace gas-heating power is approximately 400 kW and electric-heating power approximately 310 kW. These figures help identify furnace width, length and heating configuration when comparing offers. By themselves, they do not establish a sustained hourly output for a particular U-bolt.

Keep separate entries for the equipment specification upper limit and the calculated throughput for your representative workpiece. When writing throughput into a contract, confirm the workpiece, loading conditions and assessment method associated with the calculated figure.

Website case · Equipment specification for a standard-parts mesh belt quench and temper line https://www.jssngyl.cn/en/case/standard-parts-capacity

Telephone: 13052986814
Email: 997518512@qq.com
Technical authors: Suneng Industrial Furnace Engineering Team & Tang Li