How to review operating and maintenance procedures for a gas-fired trolley furnace

Published苏能工业炉工程技术团队&唐荔

The operation and maintenance procedures of the gas bogie hearth furnace, first check whether it corresponds to the equipment, the current configuration and the actual furnace loading conditions, and then see whether the maintenance responsibility, problem record and acceptance materials can be connected. Just by looking at the title of the file, you can't judge whether the procedure is applicable.

This article is used to check procurement and maintenance materials, and does not provide on-site start-stop, lifting, maintenance or commissioning steps. Specific operation and maintenance requirements shall be confirmed by the responsible professionals according to the instructions, drawings and on-site management requirements of the equipment.

Match the procedure to the heat source and furnace design

If the equipment is heated by gas, the file should be configured with the burner, gas supply, smoke exhaust and control of the furnace. The documents of electric heating equipment cannot automatically cover the requirements of the gas system.

It is also called bogie hearth furnace, and the drive and control configuration of the furnace door and furnace trolley may also be different. When checking, first match the nameplate, equipment model and actual configuration with the version of the instruction manual; a document lacks the relevant system description, which can only show that the information needs to be supplemented, and it cannot be judged that the on-site equipment does not have this system.

Verify loading limits for the specific furnace

If the shape of the workpiece changes with the furnace material or the support method, the confirmed loading range should be rechecked. The workpiece can be put into the furnace chamber, which does not mean that it is located in the effective heating area, nor does it mean that the furnace trolley, track and drive are suitable for this set of loads.

The effective heating area is the workspace confirmed according to the agreed temperature measurement conditions. When checking the loading information, the workpiece, pads and tools should be considered together; the total mass, fulcrum position and load distribution correspond to the confirmed equipment documents respectively. These conditions cannot be replaced by a set of general length, width and height margins.

Identify the basis for each maintenance interval

If the equipment configuration and usage conditions are different, the maintenance cycle in the old article cannot directly become the maintenance plan of this furnace. The project, cycle and record requirements of each component shall be approved by the responsible person in combination with the corresponding instructions, parts maintenance documents and actual use.

The person in charge of procurement or maintenance should check which document each plan is based on, who is responsible, and what records are left after completion. Writing "regular maintenance" alone can neither explain which parts are covered, nor can it help to trace the next maintenance.

After a retrofit, reconcile document revisions and issue records

If the equipment undergoes combustion system, control or furnace trolley mechanism transformation, it cannot be assumed that the original operation and maintenance documents are still fully applicable. The person in charge should check the scope of change and the corresponding information version, so as to avoid the actual configuration and documents being different.

The repair record should also distinguish the problems found, agree on the scope of handling, complete the record and review the conclusion. The record says "repair completed", which only indicates the work covered by the record; if there are other equipment performance or workpiece inspection requirements in the contract, the corresponding acceptance materials are also required, which cannot be replaced by the repair sign-off.

Checklist for the existing documents

Check the objectWhat information are you looking for?Align what?
Device identity and configurationNameplate, supply list, instruction manual versionWhether the model, heat source and actual configuration correspond
Workpiece and loading rangeLoading diagram, material information, confirmed load conditionsShape, workspace, fulcrum and load distribution
Control and protect dataCorresponding control files, alarm and protection instructionsDoes the file version override the current configuration?
Maintenance and repair planParts maintenance files, plans and historyBased on, responsible person, project and record requirements
Transformation and acceptanceChange the list, update the drawings, review and acceptance recordsScope of changes, legacy problems and confirmation results

What to prepare before contacting the supplier

You can first prepare the equipment nameplate information, the version of the instruction manual, the workpiece and loading materials, the alarm or repair records, and the specific problems you want to solve. The selection of the new furnace can be checked. Bogie hearth furnace product and program boundaries; The maintenance or renovation needs of existing equipment can be from Maintenance and renovation services Enter the communication.