Structure and materials
Keep photographs before and after removal, shell and anchor inspection records, joint and penetration details, material certificates and installation records.
Dry-out record
Where the installed material and repair design require curing or dry-out, follow the specified schedule and record the measured time–temperature curve, holding periods, moisture outlet condition, observed vapor release, abnormal events and ambient conditions. Do not transfer a generic dry-out curve between different material systems.
Surface temperature and temperature rise
A 2018 proposal uses the expression “ambient temperature + 40°C” under a wall-temperature-rise label, with 800°C steady operation stated in the lining section and thermal bridges excluded in the parameter table. A surface temperature 40°C above ambient corresponds to a 40 K rise; it is different from a 40°C absolute surface-temperature limit. The acceptance specification must resolve the source wording and define the measured quantity, operating conditions, points and exclusions before this example is used as a test limit.
Energy comparison
Compare wall temperature, heat-up time, holding power or fuel use and seals under comparable environment, load and process conditions over a complete measurement period. No universal energy-saving percentage follows from relining alone.